Thermal

THERMAL MODELLING & OVERHEATING ANALYSIS

Keeping Blue uses dynamic simulation to test how a building will perform before it is built: how it heats up, how it cools down, and how it responds to sun, wind and the way it is used. We work with architects, developers and planning consultants to resolve overheating, comfort and ventilation questions at the design stage, when changes are still cheap, and to produce the reports that planning authorities and Building Control ask for.

Click the category headings below to find out more.

Thermal Modelling & Dynamic Simulation (DSM)

Dynamic simulation predicts a building’s temperatures and energy use hour by hour, which simple calculations cannot do. We build models in IES Virtual Environment, including MacroFlo for airflow and SunCast for solar gain and shading. We use them to compare glazing, shading, fabric and ventilation options and keep capital outlay down by showing which measures make a difference. The same models support Part L compliance for non-domestic buildings where dynamic simulation is the chosen route. Where a planning condition or Building Control requires a thermal efficiency review for an extension or refurbishment, we can provide a report to discharge it.

Overheating & Thermal Comfort Analysis (TM59 / Part O)

Part O of the Building Regulations (England) requires new residential buildings, including flats, care homes and student accommodation, to limit solar gain and provide a means of removing excess heat. Compliance is shown either through the simplified method, which sets limits on glazing and ventilation, or through dynamic thermal modelling to CIBSE TM59. Planning authorities, particularly in London, also often request overheating assessments, and where mechanical cooling is proposed it generally has to be justified after passive measures have been exhausted. We carry out TM59 assessments, test mitigation options such as glazing specification, shading and ventilation openings, and report in the format authorities expect. For non-residential buildings we assess thermal comfort using CIBSE TM52. Part O does not cover extensions or existing homes, but the same analysis is useful for refurbishment and where a planning authority asks for it. As at November 2026, TM59 (2017) remains the reference for Part O compliance. CIBSE published an updated TM59:2026 in July, and we can also test designs against its future-climate weather files where a client wants evidence of resilience.

Natural & Mechanical Ventilation Strategies

Ventilation strategy affects comfort, energy use, air quality and overheating all at once, and it is much easier to get right early. We compare natural, mixed-mode and mechanical options (including MVHR and mechanical cooling) against comfort and energy performance, and use airflow modelling to size and position openings where natural ventilation is proposed. We take account of site constraints such as noise, air quality and security that limit how far windows can be opened, and of the interaction between Part F ventilation and Part O purge ventilation requirements.